2026 · Journal article · PNAS Nexus · Measuring consciousness
Atlas of intracranial EEG complexity across cortical regions and global states of consciousness
Useful Abstract only

Random forest on sleep stages micro-AUC 0.90; complexity lowest under propofol (descriptive).
How does iEEG complexity vary across regions and states? Kolmogorov complexity, permutation and spectral entropy in 106 iEEG participants; propofol in 5. Random forest on sleep stages micro-AUC 0.90; complexity lowest under propofol (descriptive).
Data and method
Kolmogorov complexity, permutation and spectral entropy in 106 iEEG participants; propofol in 5.
Results
Random forest on sleep stages micro-AUC 0.90; complexity lowest under propofol (descriptive).
Limits
Propofol n=5, not classified.
What we do with it
Complexity measures in sleep and propofol, intracranial only.
Read the original (doi:10.1093/pnasnexus/pgag048). Source checked against the original.