2026 · Paper · Journal of Neural Engineering · Measuring consciousness
Assessing consciousness by near-nerve electrostimulation in intensive rehabilitation
Background Abstract only

A combined index classified chronic unresponsive patients with leave-one-subject-out accuracy 94.7% (95% CI 77.9-99.4%), sensitivity 100%, specificity 90.9%; surface stimulation gave 63.2%.
Does near-nerve median stimulation give a better EEG marker of consciousness in prolonged DoC than surface stimulation? Selective sensory activation without motor recruitment should give cleaner evoked complexity. A combined index classified chronic unresponsive patients with leave-one-subject-out accuracy 94.7% (95% CI 77.9-99.4%), sensitivity 100%, specificity 90.9%; surface stimulation gave 63.2%. (abstract only)
Data and method
19 prolonged DoC patients, high-density EEG, evoked potentials, field power and perturbational complexity.
Results
A combined index classified chronic unresponsive patients with leave-one-subject-out accuracy 94.7% (95% CI 77.9-99.4%), sensitivity 100%, specificity 90.9%; surface stimulation gave 63.2%. (abstract only)
Limits
Single-centre pilot of 19; internal cross-validation only, as the authors say.
What we do with it
Context. Small-n perfect-looking classifiers are exactly what our held-out rules guard against.
Read the original (doi:10.1088/1741-2552/aea645). Source checked against the original.