2026 · Preprint · medRxiv/bioRxiv · Measuring consciousness
Critical dynamics in spontaneous EEG predict perturbational complexity in disorders of consciousness with measurable evoked responses
Bears on a current study Abstract only

The best-tested consciousness index needs a magnetic pulse to the head.
Resting brain signals could stand in for the stimulation-based consciousness index in some brain-injured patients, but not across all of them. The best-tested consciousness index needs a magnetic pulse to the head. This team asked whether ordinary resting EEG can predict it in 26 brain-injured patients. It could not across the whole group, only in patients whose injury was not from lack of oxygen and in those with a measurable response.
Data and method
26 patients (vascular, traumatic, anoxic). Multivariate criticality features did not generalise PCImax prediction across the full cohort; they did when restricted to non-anoxic patients and to patients with non-zero PCImax. Extends Maschke et al. 2024 (anaesthesia) to brain injury. Not peer reviewed.
Results
The best-tested consciousness index needs a magnetic pulse to the head. This team asked whether ordinary resting EEG can predict it in 26 brain-injured patients. It could not across the whole group, only in patients whose injury was not from lack of oxygen and in those with a measurable response.
What we do with it
Tempers the 2024 claim that resting EEG can replace PCI. Our out-of-sample test of that claim should report results by aetiology.
Read the original (doi:10.64898/2026.06.04.730221). Source checked against the original. Also covered in the news.