Do all sedatives promote biological sleep EEG patterns? A machine learning framework

Ramaswamy SM et al.

Bears on a current study Abstract only

Illustration: A drip bag on a stand with a line running down to a quietening trace.
Topic illustration drawn for this site, not a figure from the paper.

Sleep-trained stager on propofol and sevoflurane: AUC 0.55-0.58; dexmedetomidine 0.80.

Does a classifier trained on sleep EEG stage sedated EEG? A 44-feature sleep stager trained on the MGH sleep set (N=994) applied to propofol (36), sevoflurane (36) and dexmedetomidine (30). Sleep-trained stager on propofol and sevoflurane: AUC 0.55-0.58; dexmedetomidine 0.80.

Data and method

A 44-feature sleep stager trained on the MGH sleep set (N=994) applied to propofol (36), sevoflurane (36) and dexmedetomidine (30).

Results

Sleep-trained stager on propofol and sevoflurane: AUC 0.55-0.58; dexmedetomidine 0.80.

Limits

One multivariate model, one direction; no per-measure test, spectral baseline or surrogate.

What we do with it

The prior to cite for #5: sleep-to-propofol transfer of a multivariate stager fails.

Touches our work: Task #5 transfer