2026 · Paper · PLoS Computational Biology · Measuring consciousness
Individualised electrophysiological neural field models for the assessment of thalamocortical function in disorders of consciousness: a multicentre study
Bears on a current study Full text read

The model captured spectral features across states and showed reduced corticothalamic integrity, worse in UWS than MCS.
Can a fitted corticothalamic model explain EEG differences between MCS and UWS? Per-patient corticothalamic neural field fits should reveal reduced thalamocortical integrity (mesocircuit hypothesis). The model captured spectral features across states and showed reduced corticothalamic integrity, worse in UWS than MCS. Simulated EEG reproduced empirical complexity; permutation entropy distinguished MCS from UWS in real and simulated data. Code and replication data on GitHub (braintrak, nftsim, predictivecat/DoC_tcmodel).
Data and method
High-density EEG from two independent datasets: 203 UWS, 270 MCS, 74 controls; Robinson model fitted to spectra; simulated EEG compared on complexity metrics.
Results
The model captured spectral features across states and showed reduced corticothalamic integrity, worse in UWS than MCS. Simulated EEG reproduced empirical complexity; permutation entropy distinguished MCS from UWS in real and simulated data. Code and replication data on GitHub (braintrak, nftsim, predictivecat/DoC_tcmodel).
Limits
A model fitted to the spectrum reproduces complexity, which means complexity here is largely spectral.
What we do with it
Strong support for our spectral-confound line: if a spectrum-fitted model reproduces permutation entropy, PE carries little beyond the spectrum. Check whether the DoC_tcmodel repository holds per-patient fitted parameters or spectra; if so, it is the first open DoC-derived data for Study 2.
Read the original (doi:10.1371/journal.pcbi.1014905). Source checked against the original. Also covered in the news.